Dissolved Oxygen : In line Dissolved
Oxygen / Dissolved Oxygen Transmitter Controller for Oxygenated
Water (Alpha DO1000)
The
Alpha DO1000 in line Dissolved Oxygen
Monitor / Dissolved Oxygen Transmitter Controller offers the
user the facility to measure dissolved oxygen levels in oxygenated
water using powerful programmable functions and enhanced performance that
simplify complicated procedures associated with continuous in line
Dissolved Oxygen measurements. Advanced user-customizable features
in the Alpha Do1000's powerful SETUP function include: Two
Galvanically Isolated Scaleable 0-20/4-20 mA
Outputs for fine control, 2 independent set-points with
hysteresis protection, built-in proportional control, and noise
grounding functions. Being menu-driven, the alpha DO1000 controller
offers quick access and greater flexibility to configure measurement
functions to suit the needs of process plants that demand high-end
features at an economical price. Applications for the Alpha
DO1000 include :
Industrial :
Monitoring temperature
and control of Dissolved Oxygen in wastewater treatment and
aquaculture applications,
effluent control, water quality measurements & Oxygenated
treatment in power utilities, Water treatment in the semiconductor
industry, Boiler feed water concentration samples and
use with valves, blowers or aerators to ensure proper system
operation.
Main Features :
Built-In Programmable Limit, Proportional (Pulse Length or
Pulse Frequency) - ideal for precision process control
applications
User-Customization through Advanced Setup Menu offers
flexibility in matching the controller's functions to suit
individual's specific requirement
Readout in mg/L, pm or % saturation
Barometric and Salinity Automatic Compensation after manual
input
Hold Relay for use with float switches/flow switches and other
controllers as a failsafe function
Two Level Password Protection prevents un authorized tampering
with settings0 to 2000 Second Time Delay Adjustment on control
and alarm delays
Two Galvanically Isolated Scaleable 0-20/4-20 mA Outputs
Wash Contact Relay controls electrodes cleaning systems at
desired duration and frequency
Choice of General Purpose or Low DO measurement for wider
applications
Adjustable Hysteresis (Dead Band) prevents rapid contact
switching near set point
Non-Volatile Memory retains all stored parameters and
calibration data even if power fails
Large Dual Display shows DO with temperature simultaneously -
features clear multiple icons, set points, and status
messages
Choice of Temperature Sensor Pt100/Pt1000 with 2-wire or
3-wire temperature input selection
Easy Installation and Wiring with detachable plug-in
connectors
SPECIFICATIONS :
Product
Code
EC-DOCTP1001/2
Dissolved Oxygen Range
0.00 - 19.99 mg/l
(ppm); 0.00 to 199.9%
Resolution & Accuracy
0.01 mg/L or 0.1%
& ±1.5% Full scale
No. of Calibration Points
1 (100%
saturation) or 2 (100% and 0% saturation)
Salinity/Barometric Pressure
compensation
0.0 - 50 ppt; 555
to 808 mmHg or 74 to 108 kPA
Probe Type
Galvanic cell
Response Time
40 seconds to
achieve 93% of the reading
Temperature Range
-9.9
to 125.0 °C
Resolution &
Accuracy
0.1 °C
& ± 0.5 °C
Pressure Input
KPa/mmHg (manual
input or automatic correction)
Type of Controller Setting
Off (Monitoring);
Limit;
Proportional (Pulse Length or Pulse Frequency)
Pickup/Dropout Delay
0 to
2000 seconds
No. of Relays
Maximum Voltage
Maximum Current
High/Low Hysteresis Band
2
SPDT; 1 Alarm
250 VAC
3A;
0.1 to 1.0 mg/L or 1 to 10.0 %
R.M.S NEWS!!
We are proud to announce the launch
of the Worlds First CFR 21 Compliant - Windows CE Driven Multi-Parameter 6000 Range
of Bench Meters. Ideal for use in industries such as Pharmaceutical, Food & Drug
Manufacture and Health & Human Services. Please click
here
for details.
We accept all major credit/debit cards - please
contact us
for our best possible prices!; any questions? Why not try our
Technical Area where you will
find an in-depth explanation of many relevant aspects within the field of electrochemistry!more..