Water Disinfection :
Disinfection Probes.
Do you require to monitor your level of water
disinfection? Following an
extensive research program, We are pleased to announce a new range
of robust, industrial disinfection probes for water disinfection.
With the exception of the 4-20mA sensors, where the length is 220mm,
the sensors
have a length of 175mm and a diameter of 25mm, with plug adaptor
connection.
They are designed to fit into the available flow cells. The low
current produced by the sensors is electronically amplified in the
measurement cell. No zero point calibration is necessary, and
measurements can be taken in pressure up to 1 BAR. The sensors are
temperature compensated, and will operate in the range 0 to 45
degrees C (for the 7 Series, 0-55). The water has to be flowing to
obtain a reading, which is why flow cells are recommended.
Changes to the minimum flow rate will only slightly affect the
measurement signal.
Surfactants should not be present in the water being measured (does
not apply to the
7 Series probes).
For the dual electrode system, the measurement cell is made of gold,
and the counter and reference electrodes of silver with silver
halogenid coating. A bias voltage (polarisation) is applied between
the two electrodes. For the potentiostatic 3 electrode system, the
measurement electrode is made of
gold, the reference electrode is made of silver with a silver
halogenid coating, and the counter electrode of stainless steel.
For full details of our Water Disinfection range -
please click
here to download our catalogue.
Designed for the analysis of potable water,
swimming pools and water for industrial use, the following probes
are now available:
Click Here to go to Electrochemical Sensors Home Page |