The all new BWB-XP Flame
Photometer offers simple and reliable measurements in Flame
Photometry offering the user the capability
to simultaneously
detect Sodium (Na) - Potassium (K) - Lithium (Li) - Calcium
(Ca) - Barium (Ba) and display of all 5 elements.
The BWB-XP Flame
Photometer is a high quality, high performance instrument,
employing modern technology to ensure simple and reliable
measurements. As it is supplied as a full package
including an air compressor (not affected by high humidity),
a gas regulator, filters for Na - K - Li - Ba and Ca, both
computer and auto-sampler compatible and finally offers
switchable voltage. With
this in mind the user has no hidden costs! The Flame Photometer only requires the provision of either propane
or butane gas to enable it to be used straight out of its
package.
Please click
here to
compare the benefits from the BWB-XP over it's competitors!
Please click picture
to enlarge
BWB-XP Flame
Photometer main features:
Filters for Na,
K, Li, Ca and Ba
Simultaneous
detection and
display of all 5
elements
Internal
standard for both Na
and Li.
2 point and
multi point
calibration
Unit retains
calibration values
Flameout
detection and
automatic shutdown
Automatic
start-up routine
Self-diagnostics
on set up
Diagnostic
indicators
Detection to
ensure drain trap
filled
Modular sub
component
replacement
In built air
compressor
Replaceable
aspirator needle
Adjustable
mixing chamber
orientation
Impact bead
Computer
interface
External
Computer in-out
control
Cycle based
maintenance alerts
Moisture
separator included
Auto moisture
drain
Chart recorder
output
Gas regulator
fitted
Switchable
voltage
RoHS compliant
Auto Sampler
compatible
Please click picture to enlarge
BWB-XP
Performance
Plus
Flame
Photometer
Specification
Specification
Linearisation:
Included in the software, and available on any of the 5 elements. Achievable on both single and Multi Point calibrations.
Aspiration Rate:
3-5.5ml/min
Optimal Range:
Single Point Calibration:
Multi Point Calibration:
Na
0.05
- 60ppm
Na
0.05
- 1000ppm
K
0.05
- 100ppm
K
0.05
- 1000ppm
Li
0.1
- 50ppm
Li
0.1
- 1000ppm
Ca
2.5
- 100ppm
Ca
2.5
- 1000ppm
Ba
30
- 3000ppm
Reproducibility:
<1% coefficient of variability for 20 consecutive samples over 10 minutes (after instrument stabilisation) at concentrations of 100ppm or less.
Limits of Detection:
Na
0.02ppm.
K
0.02ppm.
Li
0.05ppm.
Ca
1.0ppm.
Ba
10ppm.
Time to Stability:
Less than 15 seconds after sample is introduced into the flame.
Drift:
Less than 1% per 30 minutes after instrument stabilisation.
Specifity:
Na/K/Li = <0.5% to each other when equal in concentration at <100ppm.
R.M.S NEWS!!
R.M.S Launch the all new BWB-XP2 Flame Photometer,
simple & reliable measurements in Flame Photometry offering the user the
capability to simultaneously detect Sodium (Na) - Potassium (K) - Lithium (Li) -
Calcium (Ca) - Barium (Ba) and display of all 5 elements. . Please click here
for details.
We accept all major credit/debit cards - please
contact us
for our best possible prices!; any questions? Why not try our
Technical Area where you will